Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
2.
Eur J Radiol ; 86: 143-162, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027741

RESUMO

Percutaneous radiofrequency ablation (RFA) for the treatment of stage I renal cell carcinoma has recently gained significant attention as the now available long-term and controlled data demonstrate that RFA can result in disease-free and cancer-specific survival comparable with partial and/or radical nephrectomy. In the non-controlled single center trials, however, the rates of treatment failure vary. Operator experience and ablation technique may explain some of the different outcomes. In the controlled trials, a major limitation is the lack of adequate randomization. In case reports, original series and overview articles, transarterial embolization (TAE) before percutaneous RFA was promising to increase tumor control and to reduce complications. The purpose of this study was to systematically review the literature on TAE as add-on to percutaneous RFA for renal tumors. Specific data regarding technique, tumor and patient characteristics as well as technical, clinical and oncologic outcomes have been analyzed. Additionally, an overview of state-of-the-art embolization materials and the radiological perspective of advanced image-guided tumor ablation (TA) will be discussed. In conclusion, TAE as add-on to percutaneous RFA is feasible and very effective and safe for the treatment of T1a tumors in difficult locations and T1b tumors. Advanced radiological techniques and technologies such as microwave ablation, innovative embolization materials and software-based solutions are now available, or will be available in the near future, to reduce the limitations of bland RFA. Clinical implementation is extremely important for performing image-guided TA as a highly standardized effective procedure even in the most challenging cases of localized renal tumors.


Assuntos
Carcinoma de Células Renais/terapia , Ablação por Cateter/métodos , Neoplasias Renais/terapia , Carcinoma de Células Renais/diagnóstico por imagem , Terapia Combinada/métodos , Embolização Terapêutica/métodos , Feminino , Humanos , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Nefrectomia/métodos , Radiografia , Cirurgia Assistida por Computador , Falha de Tratamento , Resultado do Tratamento
3.
Rofo ; 188(4): 353-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26716403

RESUMO

UNLABELLED: On February 26th, 2013 the patient law became effective in Germany. Goal of the lawmakers was a most authoritative case law for liability of malpractice and to improve enforcement of the rights of the patients. The following article contains several examples detailing legal situation. By no means should these discourage those persons who treat patients. Rather should they be sensitized to to various aspects of this increasingly important field of law. To identify relevant sources according to judicial standard research was conducted including first- and second selection. Goal was the identification of jurisdiction, literature and other various analyses that all deal with liability of malpractice and patient law within the field of Interventional Radiology--with particular focus on transarterial chemoembolization of the liver and related procedures. In summary, 89 different sources were included and analyzed. The individual who treats a patient is liable for an error in treatment if it causes injury to life, the body or the patient's health. Independent of the error in treatment the individual providing medical care is liable for mistakes made in the context of obtaining informed consent. Prerequisite is the presence of an error made when obtaining informed consent and its causality for the patient's consent for the treatment. Without an effective consent the treatment is considered illegal whether it was free of treatment error or not. The new patient law does not cause material change of the German liablity of malpractice law. KEY POINTS: •On February 26th, 2013 the new patient law came into effect. Materially, there was no fundamental remodeling of the German liability for medical malpractice. •Regarding a physician's liability for medical malpractice two different elements of an offence come into consideration: for one the liability for malpractice and, in turn, liability for errors made during medical consultation in the process of obtaining informed consent. •Forensic practice shows that patients frequently enforce both offences concurrently.


Assuntos
Consentimento Livre e Esclarecido/legislação & jurisprudência , Responsabilidade Legal , Erros Médicos/legislação & jurisprudência , Médicos/legislação & jurisprudência , Radiografia Intervencionista/normas , Radiologia Intervencionista/legislação & jurisprudência , Alemanha , Regulamentação Governamental
4.
Cardiovasc Intervent Radiol ; 38(2): 442-52, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25167958

RESUMO

PURPOSE: This study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA). METHODS: In six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 µm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL). RESULTS: Resulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm(3) for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm(3) for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features. CONCLUSIONS: Specific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.


Assuntos
Ablação por Cateter/métodos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste , Aumento da Imagem , Fígado/ultraestrutura , Micro-Ondas , Modelos Animais , Ovinos
5.
Cardiovasc Intervent Radiol ; 38(1): 191-200, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24870700

RESUMO

PURPOSE: To evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance. METHODS: After Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann-Whitney test. Histopathological differences were assessed. RESULTS: Mean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm(3), and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm(3), and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone. CONCLUSION: There is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.


Assuntos
Eletroporação/métodos , Imageamento Tridimensional/métodos , Óleo Iodado/administração & dosagem , Fígado/diagnóstico por imagem , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Modelos Animais , Suínos
6.
Cardiovasc Intervent Radiol ; 36(3): 731-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22926302

RESUMO

PURPOSE: This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. METHODS: We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. RESULTS: Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CONCLUSIONS: CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.


Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Neoplasias Renais/cirurgia , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Feminino , Humanos , Testes de Função Renal , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
7.
Radiologe ; 52(3): 267-76, 2012 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-22374085

RESUMO

PURPOSE: The compatibility of family and profession is especially difficult for employees in medical professions because of shift work and overtime. It seems that in the future women are going to represent the majority of medical professionals in Germany. Hence, with the forthcoming lack of physicians in Germany social aspects will also play a greater role in the choice of the place of employment. Therefore a statistical survey was made among employees on how they judge the compatibility of family and job and what they would like to improve. MATERIALS AND METHODS: From autumn 2009 until spring 2010 a total of 115 questionnaires were distributed to 8 different academic radiology departments. The anonymous questionnaire with partially open, partially graded questions and partially multiple answer questions was designed with the help of an expert for statistics and analytics and included questions about the employment and family situation, plans for the future, requested flexible working hours and childcare models, as well as ideas for improvement. Of the questionnaires 87 were analyzed with a specially designed access database using, for example descriptive statistics and histogram analyses. RESULTS: Of the interviewees 68% were female and 31% were male (1% not significant n.s.), 46% had children and 49% were childless (5% n.s.), 63% were medical doctors, 33% radiographers (3% other) and 82% worked full-time. Of the male respondents with children 42% indicated that their spouse was at home, 18% of female respondents with children indicated that their spouse was at home and only mothers worked part-time. Of the male respondents 73% would like to take parental leave, 44% of all respondents (70% of the male respondents and 34% of the female respondents) agreed that radiology is more compatible with family than other medical disciplines and 87% would like to have a childcare possibility in close proximity to the working place. DISCUSSION/CONCLUSIONS: In most of the families the classic role model prevails, although women are well-educated and men also set a high value on the compatibility of family and profession and would like to take parental leave and work flexible working hours. This is a chance especially for radiology.


Assuntos
Atitude do Pessoal de Saúde , Emprego/estatística & dados numéricos , Relações Familiares , Satisfação no Emprego , Corpo Clínico/estatística & dados numéricos , Médicos/estatística & dados numéricos , Tolerância ao Trabalho Programado , Adulto , Idoso , Família , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Carga de Trabalho/estatística & dados numéricos , Adulto Jovem
8.
Radiologe ; 52(1): 44-55, 2012 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-22249701

RESUMO

Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and represents the main cause of death among European patients with liver cirrhosis. Only 30-40% of patients diagnosed with HCC are candidates for curative treatment options (e.g. surgical resection, liver transplantation or ablation). The remaining majority of patients must undergo local regional and palliative therapies. Transvascular ablation of HCC takes advantage of the fact that the hypervascularized HCC receives most of its blood supply from the hepatic artery. In this context transvascular ablation describes different therapy regimens which can be assigned to four groups: cTACE (conventional transarterial chemoembolization), bland embolization (transarterial embolization TAE), DEB-TACE (TACE with drug-eluting beads, DEB) and SIRT (selective internal radiation therapy, radioembolization). Conventional TACE is the most common type of transvascular ablation and represents a combination of intra-arterial chemotherapy and embolization with occlusion of the arterial blood supply. However, there is no standardized regimen with respect to the chemotherapeutic drug, the embolic agent, the usage of lipiodol and the interval between the TACE procedures. Even the exact course of a cTACE procedure (order of chemotherapy or embolization) is not standardized. It remains unclear whether or not intra-arterial chemotherapy is definitely required as bland embolization using very small, tightly calibrated spherical particles (without intra-arterial administration of a chemotherapeutic drug) shows tumor necrosis comparable to cTACE. For DEB-TACE microparticles loaded with a chemotherapeutic drug combine the advantages of cTACE and bland embolization. Thereby, a continuing chemotherapeutic effect within the tumor might cause a further increase in intratumoral cytotoxicity and at the same time a decrease in systemic toxicity.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Embolização Terapêutica/tendências , Hemostáticos/administração & dosagem , Artéria Hepática , Neoplasias Hepáticas/terapia , Humanos , Infusões Intra-Arteriais
9.
Eur J Radiol ; 81(6): 1165-72, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21458182

RESUMO

PURPOSE: To describe angiographic, macroscopic and microscopic features of super-micro-bland particle embolization in combination with RF-ablation in kidneys. Thereby, a special focus was given on the impact of the sequence of the different procedural steps. MATERIALS AND METHODS: In ten pigs, super-micro-bland particle embolization combined with RF-ablation was carried out. Super-micro-bland embolization was performed with spherical particles of very small size and tight calibration (40 ± 10 µm). In the left kidneys, RF-ablations were performed before embolization (I). In the right kidneys, RF-ablations were performed after embolization (II). The animals were killed three hours after the procedures. Angiographic (e.g. vessel architecture), macroscopic (e.g. long and short axes of the RF-ablations) and microscopic (e.g. particle distribution) study goals were defined. RESULTS: Angiography detected almost no vessels in the center of the RF-ablations in I. In II, angiography could not define the RF-ablations. Macroscopy detected significantly larger long and short axes of the RF-ablations in II compared to I (52.2 ± 3.2 mm vs. 45.3 ± 6.9 mm [P<0.05] and 25.1 ± 3.5mm vs. 20.0 ± 1.9 mm [P<0.01], respectively). Microscopy detected irregular particle distribution at the rim of the RF-ablations in I. In II, microscopy detected homogeneous particle distribution at the rim of the RF-ablations. Microscopy detected no particles in the center of the RF-ablations in I and II. CONCLUSION: The sequence of the different procedural steps of super-micro-bland particle embolization combined with RF-ablation impacts angiographic, macroscopic and microscopic features in kidneys in the acute setting.


Assuntos
Ablação por Cateter/métodos , Embolização Terapêutica/métodos , Rim/irrigação sanguínea , Rim/patologia , Angiografia , Animais , Rim/cirurgia , Tamanho da Partícula , Radiografia Intervencionista , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Suínos
10.
Eur J Radiol ; 81(7): 1405-12, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21458939

RESUMO

OBJECTIVE: Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy (DE), standard and low-kVp contrast-enhanced computed-tomography (CT) cholangiography. MATERIALS AND METHODS: For each of 22 DECT-cholangiography examinations, 3 image datasets were analyzed as independent single-source CT-acquisitions at different tube potential, i.e. 80 kVp, 120 kVp-equivalent (linear blended dataset M0.3: 30% 80 kVp, 70% 140 kVp), and 140 kVp. Analysis comprised determination of IN, CNR and SNR in regions of interest (ROI) placed in liver parenchyma and contrasted bile ducts. IN was evaluated as mean standard deviation of 3 ROI placed within liver parenchyma (segments 6/7, 5/8, 2/3); CNR was assessed as bile duct-to-liver parenchyma ratio, and SNR as bile duct-to-image noise ratio. RD in terms of CT dose index (CTDI(vol)), dose-length product (DLP) and effective dose (ED) has been determined for each of the datasets, and compared to console prediction and scan summary values. Using phantom measurements of CTDI(vol), a method for separating comprehensive RD values of DE-acquisitions into the original RD contribution of each tube (80 kVp/140 kVp) has been developed, enabling comparison of all 3 datasets as if independently acquired using single-source "single-energy" technique. RESULTS: Highest IN was detected for 80 kVp- (38.6 ± 5.1HU), lowest for 120 kVp-equivalent linear blended M0.3-datasets (23.1 ± 3.4HU) with significant differences between all datasets (P<0.001). Highest SNR and CNR were measured for M0.3- (SNR: 14.8 ± 4.1; CNR: 11.6 ± 3.8) and 80 kVp-datasets (SNR: 13.8 ± 4.8; CNR: 11.2 ± 4.5); lowest for 140 kVp-datasets (SNR: 9.5 ± 2.5; CNR: 7.1 ± 2.3) with significant differences between M0.3- and 140 kVp-datasets as well as between 80 kVp- and 140 kVp-datasets (both P<0.001 for both CNR, SNR). CTDI(vol), DLP and ED were reduced by 50% for low-kilovoltage acquisitions (CTDI(vol): 5.5 ± 1.4 mGy; DLP: 127.8 ± 40.1 mGy cm; ED: 1.9 ± 0.6 mSv) compared to comprehensive DE-acquisitions (CTDI(vol): 11.0 ± 2.3 mGy; DLP: 253.8 ± 67.5 mGy cm; ED: 3.8 ± 1.0 mSv, tube contribution: 80 kVp: 44.5%; 140 kVp: 55.5%), and by 20% compared to conventional acquisitions at 120 kVp (CTDI(vol): 6.71 mGy; DLP: 153.5 ± 16.9 mGy cm; ED: 2.3 ± 0.3 mSv). CONCLUSIONS: Despite higher IN, low-kilovoltage CT-cholangiography reveals no significant difference with respect to CNR and SNR when compared to linear blended images yielded by DECT. Compared to DECT or conventional CT at 120 kVp, contrast-enhanced low-kVp CT cholangiography potentially allows reduction of patient dose by up to 50% or 20%, respectively. Therefore, CT-cholangiography at 80 kVp should be considered as an alternative to DECT-cholangiography whenever DECT is unavailable, or if increased image quality of DECT regarding quantitative bile duct evaluation is not needed for diagnosis.


Assuntos
Colangiografia/métodos , Transplante de Fígado , Doadores Vivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iodopamida/administração & dosagem , Iodopamida/análogos & derivados , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
11.
Eur J Radiol ; 81(9): 2007-13, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21696902

RESUMO

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.


Assuntos
Absorciometria de Fóton/métodos , Colangiografia/métodos , Seleção do Doador/métodos , Transplante de Fígado/diagnóstico por imagem , Morfina/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Analgésicos Opioides/administração & dosagem , Ductos Biliares , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
Cardiovasc Intervent Radiol ; 35(3): 653-60, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21562934

RESUMO

PURPOSE: This study was designed to analyze the effect of two different ablation modes ("temperature control" and "power control") of a microwave system on procedural outcome in porcine kidneys in vivo. METHODS: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96°C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96°C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). RESULTS: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60±0 s in group I and 102±21 s in group II. Long axis diameter was 20.3±4.6 mm in group I and 19.8±3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3±2 mm in group I and 10.5±2.4 mm in group II (NS). Circularity was 0.5±0.1 in group I and 0.5±0.1 in group II (NS). CONCLUSIONS: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.


Assuntos
Ablação por Cateter/métodos , Rim/cirurgia , Micro-Ondas/uso terapêutico , Nefrectomia/métodos , Animais , Ablação por Cateter/instrumentação , Modelos Animais , Nefrectomia/instrumentação , Suínos , Temperatura
13.
Cardiovasc Intervent Radiol ; 34(1): 156-65, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20532774

RESUMO

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume_segmented, and volume_calculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 ± 3.6 vs. 17.2 ± 1.8 mm; p < 0.001) and width (20.1 ± 2.9 vs. 12.6 ± 3.7 mm; p < 0.001); significantly larger volume_segmented (8.6 ± 3.2 vs. 3.0 ± 0.7 ml; p < 0.001) and volume_calculated (8.4 ± 3.0 ml vs. 3.3 ± 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 ± 0.10 vs. 1.48 ± 0.44; p < 0.05), sphericity (1.55 ± 0.44 vs. 1.96 ± 0.43; p < 0.01), and eccentricity (0.84 ± 0.61 vs. 1.73 ± 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 ± 0.14 vs. 0.45 ± 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.


Assuntos
Ablação por Cateter , Embolização Terapêutica , Rim/irrigação sanguínea , Rim/patologia , Artéria Renal , Angiografia , Animais , Calibragem , Feminino , Imageamento Tridimensional , Radiografia Intervencionista , Estatísticas não Paramétricas , Suínos
14.
Eur J Radiol ; 80(3): 686-91, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20971592

RESUMO

AIM: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. PATIENTS AND METHODS: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3±8.7 (40-84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. RESULTS: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3±6.1 and 3.6±2.6, respectively. Duration of the complete procedure was 87±32 min. Dose-length product and dose-area product were 1.8±1.4 Gy cm and 3.9±4.3 Gy cm2, respectively. CONCLUSIONS: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.


Assuntos
Fluoroscopia/métodos , Nefrostomia Percutânea/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Resultado do Tratamento , Ultrassonografia/métodos
15.
Eur Surg Res ; 45(1): 26-33, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20720430

RESUMO

BACKGROUND/AIMS: To determine whether intravenous morphine comedication improves bile duct visualization, diameter and/or volume applying intravenous CT cholangiography in a porcine liver model. METHODS: 12 Landrace pigs underwent intravenous CT cholangiography. Eight minutes after initiation of the contrast material infusion, either morphine sulfate (n = 6 animals) or normal saline (n = 6 animals) was administered. Eighteen consecutive CT scans of the liver were acquired with 2-min intervals starting with initiation of the contrast material infusion. Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were determined. RESULTS: Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were not significantly different when the morphine group was compared to the normal saline group. Maximum bile duct visualization scores ranged between 4.00 ± 0.00 and 2.83 ± 1.47. Maximum bile duct diameters ranged between 6.77 ± 0.40 and 2.10 ± 1.35 mm. Maximum bile duct volume was 16.41 ± 7.33 ml in the morphine group and 16.79 ± 5.65 ml in the normal saline group. CONCLUSION: Intravenous morphine comedication failed to improve bile duct visualization and to increase bile duct diameter and volume applying CT cholangiography.


Assuntos
Morfina/administração & dosagem , Analgésicos Opioides/administração & dosagem , Animais , Colecistografia/métodos , Ducto Colédoco/anatomia & histologia , Ducto Colédoco/diagnóstico por imagem , Ducto Cístico/diagnóstico por imagem , Infusões Intravenosas , Radiografia Abdominal , Suínos , Tomografia Computadorizada por Raios X/métodos
16.
J Hepatobiliary Pancreat Sci ; 17(5): 666-72, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20703845

RESUMO

BACKGROUND/PURPOSE: To assess the feasibility of intravenous 64-multi-detector row computed tomography (CT)-cholangiography of porcine livers with definition of the temporal window for optimal bile duct delineation. METHODS: Six healthy Landrace pigs, each weighing 28.97 +/- 2.99 kg, underwent 64-multi-detector row CT-cholangiography. Each pig was infused with 50 ml of meglumine iotroxate continuously over a period of 20 min and, starting with the initiation of the infusion, 18 consecutive CT scans of the abdomen at 2-min intervals were acquired. All series were evaluated for bile duct visualization scores and maximum bile duct diameters as primary study goals and bile duct attenuation and liver enhancement as secondary study goals. RESULTS: Of the 16 analyzed biliary tract segments, maximum bile duct visualization scores ranged between 4.00 +/- 0.00 and 2.83 +/- 1.47. Time to maximum bile duct visualization scores ranged between 10 and 34 min. Average bile duct visualization scores for the 10- to 34-min interval ranged between 3.99 +/- 0.05 and 2.78 +/- 0.10. Maximum bile duct diameters ranged between 6.47 +/- 1.05 and 2.65 +/- 2.23 mm. Time to maximum bile duct diameters ranged between 24 and 34 min. Average bile duct diameters for the 10- to 34-min interval ranged between 6.00 +/- 0.38 and 2.40 +/- 0.13 mm. CONCLUSIONS: Intravenous 64-multi-detector row CT-cholangiography of non-diseased porcine liver is feasible, with the best bile duct delineation acquired between 10 and 34 min after initiation of the contrast agent infusion.


Assuntos
Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Colangiografia/métodos , Meios de Contraste/administração & dosagem , Iodopamida/análogos & derivados , Hepatopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Iodopamida/administração & dosagem , Hepatopatias/cirurgia , Reprodutibilidade dos Testes , Suínos
17.
Cardiovasc Intervent Radiol ; 33(3): 498-508, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20049594

RESUMO

The purpose of this study was to evaluate the technical and clinical success of superselective embolization in patients with life-threatening arterial renal hemorrhage undergoing preinterventional CT angiography. Forty-three patients with clinical signs of life-threatening arterial renal hemorrhage underwent CT angiography and catheter angiography. Superselective embolization was indicated in the case of a positive catheter angiography. Primary study goals were technical and clinical success of superselective embolization. Secondary study goals were CT angiographic and catheter angiographic image findings and clinical follow-up. The mean time interval between CT angiography and catheter angiography was 8.3 +/- 10.3 h (range, 0.2-34.1 h). Arterial renal hemorrhage was identified with CT angiography in 42 of 43 patients (98%) and catheter angiography in 39 of 43 patients (91%) (overview angiography in 4 of 43 patients [9%], selective angiography in 16 of 43 patients [37%], and superselective angiography in 39 of 43 patients [91%]). Superselective embolization was performed in 39 of 43 patients (91%) and technically successful in 37 of 39 patients (95%). Therefore, coil embolization was performed in 13 of 37 patients (35%), liquid embolization in 9 of 37 patients (24%), particulate embolization in 1 of 37 patients (3%), and a combination in 14 of 37 patients (38%). Clinical failure occurred in 8 of 39 patients (21%) and procedure-related complications in 2 of 39 patients (5%). The 30-day mortality rate was 3%. Hemoglobin decreased significantly prior to intervention (P < 0.001) and increased significantly after intervention (P < 0.005). In conclusion, superselective embolization is effective, reliable, and safe in patients with life-threatening arterial renal hemorrhage. In contrast to overview and selective angiography, only superselective angiography allows reliable detection of arterial renal hemorrhage. Preinterventional CT angiography is excellent for detection and localization of arterial renal hemorrhage and appropriate for guidance of the embolization procedure.


Assuntos
Angiografia/métodos , Embolização Terapêutica/métodos , Hemorragia/diagnóstico por imagem , Hemorragia/terapia , Artéria Renal , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
18.
Cardiovasc Intervent Radiol ; 33(3): 565-75, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20033165

RESUMO

The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 microm). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury, vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 microm. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 microm and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.


Assuntos
Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/prevenção & controle , Artéria Ilíaca , Desenho de Prótese , Stents , Angiografia , Animais , Modelos Animais de Doenças , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/patologia , Artéria Ilíaca/patologia , Masculino , Coelhos , Stents/efeitos adversos
19.
Pediatr Transplant ; 12(5): 606-10, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18652621

RESUMO

Early HAT is the most frequent and severe vascular complication following liver transplantation. It is one of the major causes of graft failure and mortality. Endovascular thrombolytic treatment in patients with thrombotic complications after liver transplantation is an attractive alternative to open surgery as lower morbidity and mortality rates are reported for it. PTA following transcatheter thrombolysis has been successfully used to treat HAT in adults. To the best of our knowledge, there have not been any reports of a successful transcatheter thrombolysis using interventional radiological techniques in a patient only four months old. The present report describes the successful endovascular emergency treatment of a HAT three days after DD split liver transplantation.


Assuntos
Angioplastia com Balão/métodos , Artérias/patologia , Artéria Hepática/patologia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Terapia Trombolítica/métodos , Trombose/terapia , Síndrome de Alagille/terapia , Feminino , Rejeição de Enxerto , Artéria Hepática/cirurgia , Humanos , Lactente , Fígado/diagnóstico por imagem , Fígado/enzimologia , Cirrose Hepática/terapia , Resultado do Tratamento , Ultrassonografia Doppler em Cores/métodos
20.
Rofo ; 179(6): 593-600, 2007 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-17492540

RESUMO

PURPOSE: The purpose of this study was to evaluate the clinical long-term success of uterine artery embolization (UAE) in patients with symptomatic fibroids using spherical particles (Embosphere). MATERIALS AND METHODS: 34 consecutive patients treated with UAE were initially enrolled in the study which had the following study goals 1) 1-year follow-up MRI evaluation of the fibroid behavior and 2) clinical long-term success due to standardized assessment of the main fibroid-related symptoms (hypermenorrhoea, dysmenorrhoea and dysuria) of the patients' individual overall health status and their therapy satisfaction at 1-year, 2- year and 3-year intervals after UAE. RESULTS: Technical success was achieved in all procedures. Four patients had to be excluded from the long-term evaluation schedule: one because of a hysterectomy due to bleeding after 6 weeks, 3 patients were not available for the designated minimum follow-up interval. The preinterventional severe hypermenorrhoea (n = 27) with a score of 4.4 +/- 0.7 (5 = extreme menstrual bleeding) decreased after one year to 2.1 +/- 0.5 (p = 0.0001), after two years to 1.7 +/- 0.5 (p = 0.0042) and after three years to 1.3 +/- 0.6 (p = 0.0001). The preinterventional dysmenorrhoea (n = 15) with a score of 3.1 +/- 1.5 (3 = distinctly increased dysmenorrhoea) decreased after one year to 1.1 +/- 0.3 (p = 0.0001), after two years to 1.2 +/- 0.2 and after three years to 1.2 +/- 0.4 (p = 0.148). The pretreatment dysuria (n = 12) with a preinterventional score of 3.1 +/- 1.5 (3 = distinctly increased dysuria) decreased after one year to 1.1 +/- 0.3 (p = 0.0069) and remained after two years at 1.1 +/- 0.2 and after three years at 1.2 +/- 0.4 (p = 0.905). The initial overall health status was 54.7 +/- 20.1 (maximal value 100). After one year it rised to 90.5 +/- 15.4 (p = 0.0001), was 91.8 +/- 5.6 after two years and was 91.3 +/- 8.5 (p = 0.8578) after three years. The satisfaction with the therapy was 2.9 +/- 0.2 after one year, 2.6 +/- 0.3 after two years and 2.7 +/- 0.5 (3 = extremely satisfied) after three years. We observed 12 minor and 3 major complications (one hysterectomy, one fibroid expulsion associated with a short bleeding episode and one transient amenorrhoea for three months). All patients benefited clinically from the procedure and a clinical benefit was achieved in all cases. CONCLUSION: Under controlled study conditions, flow-guided UAE with spherical embolization particles achieves high clinical success for all relevant clinical symptoms without negative changes during follow-up after at least 3 years. Accordingly, patient therapy satisfaction remained extraordinarily high even 3 years after UAE.


Assuntos
Embolização Terapêutica/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Dismenorreia/etiologia , Feminino , Seguimentos , Humanos , Menorragia/etiologia , Qualidade de Vida , Radiografia , Fatores de Tempo , Transtornos Urinários/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...